DIN Standard Chains
Force Chain | Wire Diameter | Inner Length | Inside Width | Outside Width | Inner Length | Appr. | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Articel No | Ø(dn) | Tolerance | t | Tolerance | b1 min. | b2 max. | 11 x t | Tolerance | Kg / Mtr | ||
FC.766.DG3.R.04.W | 4 | ± 0,20 | 16 | + 0,3 | - 0,2 | 4,8 | 13,6 | 176,0 | + 0,8 | - 0,4 | 0,32 |
FC.766.DG3.R.05.W | 5 | ± 0,20 | 18,5 | + 0,4 | - 0,2 | 6,0 | 17,0 | 203,5 | + 0,9 | - 0,5 | 0,50 |
FC.766.DG3.R.06.W | 6 | ± 0,20 | 18,5 | + 0,4 | - 0,2 | 7,2 | 20,4 | 203,5 | + 0,9 | - 0,5 | 0,80 |
FC.766.DG3.R.07.W | 7 | ± 0,30 | 22 | + 0,4 | - 0,2 | 8,4 | 23,8 | 242,0 | + 1,1 | - 0,5 | 1,10 |
FC.766.DG3.R.08.W | 8 | ± 0,30 | 24 | + 0,4 | - 0,2 | 9,6 | 27,2 | 264,0 | + 1,2 | - 0,6 | 1,40 |
FC.766.DG3.R.09.W | 9 | ± 0,40 | 27 | + 0,5 | - 0,3 | 10,8 | 30,6 | 297,0 | + 1,3 | - 0,7 | 1,80 |
FC.766.DG3.R.10.W | 10 | ± 0,40 | 28 | + 0,5 | - 0,3 | 12,0 | 36,0 | 308,0 | + 1,4 | - 0,7 | 2,30 |
FC.766.DG3.R.11.W | 11 | ± 0,40 | 31 | + 0,5 | - 0,3 | 13,2 | 40,0 | 341,0 | + 1,5 | - 0,8 | 2,70 |
FC.766.DG3.R.13.W | 13 | ± 0,50 | 36 | + 0,6 | - 0,3 | 15,6 | 47,0 | 396,0 | + 1,7 | - 0,9 | 3,90 |
FC.766.DG3.R.14.W | 14 | ± 0,60 | 41 | + 0,7 | - 0,4 | 16,8 | 50,0 | 451,0 | + 2,0 | - 1,0 | 4,40 |
FC.766.DG3.R.16.W | 16 | ± 0,60 | 45 | + 0,8 | - 0,4 | 19,2 | 58,0 | 495,0 | + 2,2 | - 1,1 | 5,80 |
Wire Diameter | Working Load Limit | Test Force | Breaking Load | Bending Test |
---|---|---|---|---|
Ø ( dn) mm | WLL ( Kg ) max. | MTF ( kN ) | BLL ( kN ) min. | f ( mm ) min. |
4,0 | 200 | 5,0 | 8,0 | 3,0 |
5,0 | 320 | 8,0 | 12,5 | 4,0 |
6,0 | 400 | 10,0 | 16,0 | 5,0 |
7,0 | 630 | 16,0 | 25,0 | 6,0 |
8,0 | 800 | 20,0 | 32,0 | 7,0 |
9,0 | 1000 | 25,0 | 40,0 | 7,0 |
10,0 | 1250 | 32,0 | 50,0 | 8,0 |
11,0 | 1600 | 40,0 | 63,0 | 9,0 |
13,0 | 2000 | 50,0 | 80,0 | 11,0 |
14,0 | 2500 | 63,0 | 100,0 | 12,0 |
16,0 | 3200 | 80,0 | 125,0 | 13,0 |
Security Level | 1 / 2,5 / 4 | ||||||
Working Load Limit ( WLL ) | 75 N / mm2 | ||||||
Manufacture Test Force ( MTF ) | 188 N / mm2 | ||||||
Breaking Load Limit ( BLL ) | 300 N / mm2 |